Tuesday, March 3, 2015

MX-ONE Number Presentation 2

On a client using a Primary Rate ISDN, the CLOP was incorrect because the circuit numbering "clashed" with the extension numbering:

- 3125xxx is the DID range.
- 5xxx is the extension range (thus no DID tables need to be setup)
- 31255xxx is the resulting displayed CLOP

number_conversion_initiate -conversiontype 1 -numbertype 10 -entry 5 -truncate 1

The above removed the extra 5 for each extension as they call out.

It is worth noting that:
1. I did not use RONDI.
2. I set the Public Exchange number (=312) and Common Public Directory Number (=312) in the Web GUI (MTS)